400V 415V 63A~800A 3P 4Poles MCCB Moulded Case Circuit Breaker
-
Payment
-
Origin
China Mainland
-
Minimum Order
1
-
Packing
Pieces
- Contact Now Start Order
- Description
Product Detail
Welcome to wholesale the low price and high quality 400v 415v 63a~800a 3p 4poles mccb moulded case circuit breaker with CHANGAN GROUP. We are one of the leading manufacturers and suppliers of various low voltage electrical apparatus in China. And the free sample and the customized service are also available.
CAM1 Series MCCB
Application
CAM1 series moulded case circuit breaker (named as MCCB in the following) is a new type breaker which is used for infrequent exchange and startup in AC 60Hz condition. The MCCB is of protection function in overloading, short-circuit, and under voltage situation to protect circuit system and power device from damage.
The MCCB can be devided into L; M; H type according to their rated limit short circuit breaking capacity.
The MCCB is advantageous for its compact body, high breaking capacity (some even on flying arc), short arc-casing and superior aseismatic function.
The product complies with IEC60947-2, GB14048.2
Specification
Type | CAM1-63L/CAM1-63M | CAM1-100L/CAM1-100M | CAM1-225/CAM1-250 | |||||||||||||||
Rated frame level current Inm(A) | 63 | 100 | 225 | |||||||||||||||
Rated current In(A) | 10,12,16,20,25 | 16,20,25,32,40, | 125,160,180,200,225,250 | |||||||||||||||
Rated insulated voltage Ui (AC V) | 500 | 800 | 800 | |||||||||||||||
Rated impulse stand voltage Uimp(V) | 8000 | 8000 | 8000 | |||||||||||||||
Rated working voltage Ue (AC V) | 400/415 | 400/415 | 400/415 | |||||||||||||||
Poles | 3 | 4 | 3 | 4 | 3 | 4 | ||||||||||||
Rated limited short circuit breaking capacity level | L | M | L | M | L | M | L | M | L | M | L | M | ||||||
Rated imited short circuit breaking capacity Icu(KA) | 400/415V | 20 | 30 | 20 | 30 | 30 | 50 | 30 | 50 | 35 | 50 | 35 | 50 | |||||
Rated working short circuit breaking capacity Ics(KA) | 400/415V | 15 | 22.5 | 15 | 22.5 | 22.5 | 37.5 | 22.5 | 37.5 | 26.25 | 37.5 | 26.25 | 37.5 | |||||
Operation characteristic (Times) | Connected | 2000 | 2000 | 2000 | ||||||||||||||
Break | 10000 | 10000 | 10000 | |||||||||||||||
Outlook dimension | L | 135 | 150 | 165 | ||||||||||||||
W | 78 | 103 | 92 | 122 | 107 | 142 | ||||||||||||
H | 73.5 | 81.5 | 72 | 88 | 86 | 103 | ||||||||||||
Weight (g) | 735 | 846 | 1464 | 1952 | 1257 | 1493 | 1493 | 1900 | 1714 | 2014 | 1900 | 2014 | ||||||
Arcing distance (mm) | 0, =50 | 0, =50 | 0, =50 |
Type | CAM1-400M CAM1-400H | CAM1-630M CAM1-630H | CAM1-800H | |||||||||
Rated frame level current Inm(A) | 400 | 630 | 800 | |||||||||
Rated current In(A) | 225,250,315,350,400 | 400,500,630 | 630,700,800 | |||||||||
Rated insulated voltage Ui (AC V) | 800 | 800 | 800 | |||||||||
Rated impulse stand voltage Uimp(V) | 8000 | 8000 | 8000 | |||||||||
Rated working voltage Ue (AC V) | 400/415 | 400/415 | 400/415 | |||||||||
Poles | 3 | 4 | 3 | 4 | 3 | 4 | ||||||
Rated limited short circuit breaking capacity level | L | M | L | M | L | M | L | M | H | H | ||
Rated imited short circuit breaking capacity Icu(KA) | 400/415V | 50 | 70 | 50 | 70 | 50 | 70 | 50 | 70 | 80 | 80 | |
Rated working short circuit breaking capacity Ics(KA) | 400/415V | 37.5 | 52.5 | 37.5 | 52.5 | 37.5 | 52.5 | 37.5 | 52.5 | 60 | 60 | |
Operation characteristic (Times) | Connected | 1000 | 1000 | 500 | ||||||||
Break | 5000 | 4000 | 3000 | |||||||||
Outlook dimension | L | 257 | 270 | 280 | ||||||||
W | 150 | 198 | 182 | 240 | 210 | 280 | ||||||
H | 106.5 | 110 | 11.5 | |||||||||
Weight (g) | 5420 | 7743 | 6116 | 7116 | 7116 | 9929 | 8526 | 11731 | ||||
Arcing distance (mm) | 0, =50 | 0, =100 | 0, =100 |